  • 34 BLOKSET低压开关柜.jpg

Blokset Low-Voltage Switchgear

The Blokset cabinet is a branded product of Schneider Electric France. It offers a wide range of cabinet configurations to meet diverse application requirements. Its frame is assembled from standardized prefabricated components, allowing for the creation of switchgear cabinets in various widths and depths through combinations of basic and expansion frames.


Category:

Low-Voltage Switchgear

Keywords:

Blokset Low-Voltage Switchgear



Detailed Introduction Technical Specifications

The Blokset cabinet is a branded product of Schneider Electric France. It offers a wide range of cabinet configurations to meet diverse application requirements. The cabinet frame is assembled from standardized prefabricated components, allowing for the creation of switchgear cabinets in various widths and depths through combinations of basic and expansion frames. The switchgear cabinet comprises four distinct compartments: the busbar compartment, the component compartment, the outgoing cable compartment, and the accessory compartment. Feeder units are available in three structural configurations: fixed, plug-in, and drawer-type.
It is suitable for all power generation, distribution, and consumption sites, performing functions such as power collection and distribution at 660 V/220 V, system monitoring and protection, and control and protection of electrical facilities and equipment in the power systems of power plants, substations, industrial and mining enterprises, hotels, ports, and other end-users.

 

A wide range of cabinet configurations are available to meet the needs of various applications, enabling functions such as power distribution, motor protection, and power factor correction, and are suitable for all low-voltage systems that require high reliability.
D cabinet installation density: 3 MT16 units, 9 NSX630 units, and 24 NSX250 units; U cabinet: 34 motor control circuits.
Ventilation Design for the Top of the Patent Cabinet
The product has successfully passed the 100 kA internal arc fault test, electromagnetic compatibility test, seismic resistance test at intensity 9, and high-altitude test at 5,000 meters, thereby ensuring its safety.

 

Technical Specifications

Application D DC C
Type 132 Type 132 Type 134
Power distribution
Electric Motor Control    
Standard
Type Testing Section IEC 60439-1/VDE 0660500 Part/DIN 41-488/BS 5486/EN 60439-1
Seismic Resistance Unified Building Code / California Building Code
Internal Arc Withstand Capability AS 3439/1
Electrical Characteristics
Rated voltage
Rated Insulation Voltage (V AC) 1000
Rated Operating Voltage (V AC) 690
Rated Impulse Withstand Voltage (kV) 12
Overvoltage Category IV
Pollution Level 3
Frequency (Hz) Below 400
Rated current
Main bus Single busbar Double busbars -
Rated Current (A) Below 4000A Below 6300A -
Rated Peak Withstand Current (kA) 63/105/187 220-
Rated short-time withstand current (kA RMS/1 s) 30/50/85 100 
Distribution busbar
Rated current (A) Below 3200A  630
Rated Peak Withstand Current (kA) 63/105/187   40/53
Rated short-time withstand current (kA RMS/1 s) 30/50/85   20/25
Output
Electric motor - -
Power distribution Below 6300A   Below 630A
Mechanical Properties
Total height 22002200 1000/1400
Effective height (one module = 50 mm) 40 modules 40 modules 20/28 modules
Width (mm) 700/900/1100/1200/1300 700700
Depth 400/600/1000 400/600 200/300
Functional Unit FFF FFF FFF
IEC 60439-1 Separated Type 1/2b/3b/41/2b1
IEC 60529 Ingress Protection Ratings IP20/31/42/54IP20/31/42/54IP42/54
Surface protection Epoxy Powder Polymerization at High Temperatures
Standard color RAL9002/7016RAL9002/7016RAL9002/7016
Application Mf Mw Ms
Type 132 Type 132 Type 132
Power distribution    
Electric Motor Control
Standard
Type Testing Section IEC 60439-1/VDE 0660500 Part/DIN 41-488/BS 5486/EN 60439-1
Seismic Resistance Unified Building Code / California Building Code
Internal Arc Withstand Capability AS 3439/1
Electrical Characteristics
Rated voltage
Rated Insulation Voltage (V AC) 1000
Rated Operating Voltage (V AC) 690
Rated Impulse Withstand Voltage (kV) 12
Overvoltage Category IV
Pollution Level 3
Frequency (Hz) Below 400
Rated current
Main bus Single busbar Double busbars -
Rated Current (A) Below 4000A Below 6300A -
Rated Peak Withstand Current (kA) 63/105/187 220-
Rated short-time withstand current (kA RMS/1 s) 30/50/85 100 
Distribution busbar
Rated current (A) Below 3200A 1000A Below 3200A
Rated Peak Withstand Current (kA) 63/105/187 187 63/105/187
Rated short-time withstand current (kA RMS/1 s) 30/50/85 85 30/50/85
Output
Electric motor Below 250 kW Below 250 kW Below 160 kW
Power distribution Same as Type D Below 250A  
Mechanical Properties
Total height 220022002200
Effective height (one module = 50 mm) 40 modules 12 units, 3 modules per unit 40 modules
Width (mm) 700/900/1100/1300 700/900 700/900/1100
Depth 400/600/1000 600/1000 400/600/1000
Functional Unit FFF World Wide Web FFF
IEC 60439-1 Separated Type 1/2b/3b/43b/41/2b/3b/4
IEC 60529 Ingress Protection Ratings IP20/31/42/54IP20/31/42/54IP20/31/42
Surface protection Epoxy Powder Polymerization at High Temperatures
Standard color RAL9002/7016RAL9002/7016RAL9002/7016

Consult now

Submit a message