LW39-126 Outdoor AC High-Voltage SF6 Circuit Breaker
The LW39-126 outdoor AC high-voltage porcelain-pole SF6 circuit breaker is designed for use in power systems with a frequency of 50 Hz and a rated system voltage of 110 kV. It serves as a key piece of electrical equipment for control and protection in power plants and substations.
Category:
High-voltage switchgear
Keywords:
LW39-126 Outdoor AC High-Voltage SF6 Circuit Breaker
The LW39-126 outdoor AC high-voltage porcelain-pole SF6 circuit breaker is designed for use in power systems with a frequency of 50 Hz and a rated system voltage of 110 kV. It serves as a key piece of electrical equipment in power plants and substations, used for controlling and protecting the system. The circuit breaker employs the thermal expansion self-blast arc-extinguishing principle and is filled internally with SF6 gas, which offers exceptional arc-extinguishing and electrical insulation properties. All sealing points utilize dual O-ring seals, effectively preventing gas leakage. Additionally, it is equipped with a CT30-type spring-operated mechanism that enables synchronized three-phase mechanical operation.
The switching performance is stable, reliably interrupting faults such as outgoing-line short circuits, loss of synchronism, and near-zone faults.
The arc-extinguishing chamber features a simple, reliable design and is easy to maintain;
It boasts a long electrical lifespan, capable of fully interrupting rated current up to 20 times, and requires no maintenance for 10 years under normal operating conditions.
It requires minimal operating force and features a simple, reliable, and compact spring-operated mechanism.
The gas has a low rated filling pressure, making it suitable for use in low-temperature conditions.
Small footprint;
Low noise levels make it suitable for residential areas;
Long maintenance cycles with minimal upkeep requirements;
On-site installation and commissioning take a short time.
Number of fracture points per pole | Name | Unit | Parameters | |||||
1 | System Nominal Voltage | kV | 110 | |||||
2 | Rated Voltage | kV | 126 | |||||
3 | Rated frequency | Hz | 50/60 | |||||
4 | Rated current | A | 3150 | |||||
5 | Rated Short-Circuit Interrupting Current | kA | 31.5 | 40 | ||||
6 | Rated Short-Circuit Making Current (Peak) | kA | 80 | 100 | ||||
7 | Rated Short-Time Withstand Current (Thermal Stability Current) | kA | 31.5 | 40 | ||||
8 | Rated Peak Withstand Current (Dynamic Stability Current) | kA | 80 | 100 | ||||
9 | Rated Short-Circuit Duration (Thermal Stability Time) | s | 4 | 3 | ||||
10 | First-time homeownership rate |
| 1.5 | |||||
11 | Lightning Impulse Withstand Voltage | kV | 650 | |||||
12 | 1-minute power frequency withstand voltage | kV | 275 | |||||
13 | Creepage Distance | mm/kV | 25/31 | |||||
14 | Rated Operating Sequence |
| O-0.3s-CO-180s-CO | |||||
15 | Closing time | Ms. | ≤110 | |||||
16 | Breaker Operation Time | Ms. | ≤65 | |||||
17 | Combine—Split Time | Ms. | ≤85 | |||||
18 | Closing time | Ms. | 80 ± 5 | |||||
19 | Trip-off time | Ms. | 33 ± 7 | |||||
20 | Number of断口 per pole | One | 1 | |||||
21 | Main circuit resistance | μΩ | ≤45 | |||||
22 | Mechanical Life | Next time | 10000 | |||||
23 | SF6 gas pressure (20°C) | Rated value | Mpa | 0.55 | 0.60 | |||
| Alarm threshold | Mpa | 0.50 | 0.55 | |||||
| Lock-in value | Mpa | 0.45 | 0.50 | |||||
24 | SF6 Moisture Content | ppm (V/V) | ≤150 | |||||
25 | SF6 Annual Leakage Rate |
| ≤1% | |||||
26 | Auxiliary circuit voltage | V | AC220 | |||||
27 | Closing coil | Voltage | V | DC220 | DC110 | |||
| Electric current | A | 2 | 3.3 | |||||
28 | Trip coil | Voltage | V | DC220 | DC110 | |||
| Electric current | A | 2 | 5.8 | |||||
29 | Energy-storage motor | Voltage | V | AC220/DC220 | ||||
| Power | W | 600 | ||||||
30 | Energy storage time | s | ≤15 | |||||